Circular Gaussian / super-Gaussian through a circular aperture
absolute irradiance · x-decentered beamAperture results
Calculate to see results.The report includes the inputs, results, warnings and plots, including the M² fit when calculated. Open it in a browser to print or save as PDF.
White circle: aperture. White +: aperture centre. Red ×: beam centre. Color shows untruncated irradiance in kW/cm².
Dashed lines: aperture edges. Red dotted line: beam centre. The profile is untruncated.
Through-focus M² fit
ASM simulation of the clipped beam aboveA quadratic focusing phase, centred on the incident beam, is chosen automatically to target a resolvable focus on a 1024 grid. The same curvature is used at every grid size. Propagation starts immediately after the hard aperture; z is distance from that plane. The incident wavefront was not specified, so this is a simulated focusing system, not a measurement of the actual wavefront.
Dots: ASM diameters from second moments about each plane’s centroid. Lines: separate quadratic fits of D4σ² versus z. Blue: X; green: Y.
In ideal paraxial theory, a hard aperture with nonzero edge intensity has a divergent angular second moment. The fitted M² depends on the numerical grid, finite window and band-limit. The band-limit is applied independently at each propagation distance and can discard real diffraction, even when little power is rejected. Compare grid sizes and filter settings; these results are not ISO-certified measurements.
The aperture calculation uses the MATLAB midpoint grid (1501 × 1501 by default) and an exact maximum-edge irradiance. The sampled aperture boundary also limits accuracy, especially for small clipped fractions. Compare results with a finer grid and independently verify critical cases; the numerical total-power check alone does not establish convergence.
D4σ refers to the untruncated continuous beam for every order. Peak irradiance is normalized to the specified total power over the infinite beam, not to the sampled grid. High orders have sharp edges and may require a finer grid; low orders have long tails and can also be difficult to sample.