Configurations
Keplerian starting point, adapted from the paraxial toolGaussian beam inputs
coherent, diffraction-limited beam in airOptical sequence
elements are encountered in order; distances are in metres| # | Element | Name | Value (m) | Decenter x (m) | Order |
|---|
Intensity along optical path
central y = 0 slice · normalized independently at each planeClick the plot to select a plane. Green lines: lenses; amber: apertures; purple: observers. Each plane is normalized to its own 2D peak, so the colors do not show absolute intensity changes along the path. Linear and square-root displays cover 0–100% of each peak.
Selected plane
2D intensity · normalized to this displayed plane's peak| Position | — |
|---|---|
| Peak intensity | — |
| Integrated intensity | — |
| Centroid x | — |
| D4σ radius (x) | — |
The 2D plot uses the selected intensity scale and is normalized to its own displayed peak; zero intensity remains black. Positive x is to the right in the 2D plot. Reported peak intensity is relative to the input waist's peak. Integrated intensity uses mm² and is not calibrated optical power. D4σ radius is 2σₓ about the intensity centroid; it is a Gaussian 1/e² radius only for a Gaussian profile. At 1024 grid size, the 2D image is averaged to 512 × 512 pixels to limit memory; propagation, the path slice and metrics use the full grid.
Model and sampling notes
ASM propagates a sampled complex field in air using the angular spectrum transfer function. Lenses apply a paraxial thin-lens phase; apertures are circular hard masks. The preset includes a 1 mm stop at the common focus. There is no refraction through thick lenses, aberration, polarization or M² > 1 model.
Band-limiting rejects propagating spatial frequencies whose transfer-function phase changes by more than π per frequency bin in either direction, using the distance from the start of each space. The reported fraction is the largest fraction of input spectral power rejected in any one propagation, not a physical aperture loss. The filter can remove genuine fine detail and power; compare with it disabled and check convergence. Aperture-edge diffraction remains.
Automatic sizing starts with the input beam and repeats the entire propagation with a 50% wider window until no sampled plane has more than 0.1% of its power in the outer edge region, or five attempts have been made. The grid size stays fixed, so increasing the window reduces spatial resolution. This edge test is a heuristic, not a guarantee: wraparound between sampled planes and undersampling can go undetected. Check convergence with a larger window and grid.
The FFT assumes a periodic transverse window: light reaching its edges wraps around. A warning is shown when more than 0.1% of a sampled plane's intensity lies in its outer edge region. This is not a guarantee of accuracy: check convergence by increasing both window width and grid resolution, and check that focused spots and lens phase are adequately sampled.