Design inputs
All dimensions in mmIn image-size mode the diameter ratio sets the magnification; it is independent of the beam diameter. In ABCD mode the front diameter only sets the illustrative ray height. The matrix relates [height (mm), angle (rad)] at the front and back planes and must satisfy AD − BC = 1. Total distance is the front distance plus first-to-last lens length plus back distance. The waist position is signed from the front plane: positive is downstream.
Design result
Find a design to see results.| Element | Position from front plane (mm) | Distance from previous (mm) | Focal length (mm) | Beam D4σ (mm) | Peak (kW/cm²) |
|---|
The search minimizes the highest peak irradiance on any lens, subject to the peak limit. Positive f is converging; negative f is diverging.
L2–L3 compound principal planes
Blue rays start at the same height with different illustrative angles. They meet at the back plane only when the system is imaging. These geometric rays are separate from the Gaussian beam.
Gaussian-equivalent beam envelope
The curves show ±D4σ/2. Peak irradiance is checked at each thin lens, using the incident beam before the lens.
Model and limitations
Thin lenses in air and paraxial rays. B = 0 means the planes are conjugate (imaging), with signed magnification A; C = 0 means the system is afocal. Both can hold at once. Peak irradiance assumes a circular Gaussian intensity profile: I₀ = 2P/(πw²), with w = D4σ/2. M² propagates the second-moment diameter; for M² > 1, the reported peak is a Gaussian-equivalent estimate, not a guaranteed actual peak, because M² alone does not determine the intensity profile. No lens absorption, clipping, thickness or aberrations are modeled. The search minimizes the maximum lens peak among sampled feasible layouts, using spacing as a tie-breaker. It does not guarantee a global optimum; failure to find a layout does not prove none exists. Verify results independently.